解析模塊化逆變電源的優點

發布時間:作者:cobinet keystone jack瀏覽:698次來源:千家綜合布線(xian)網
CobiNet(寧波)推薦文章:

1.系統的高可靠(kao)性

交流(liu)供(gong)(gong)(gong)電(dian)(dian)(dian)(dian)可(ke)靠性是通(tong)(tong)信(xin)(xin)系統(tong)的(de)(de)(de)最基本要求,很多供(gong)(gong)(gong)電(dian)(dian)(dian)(dian)故障導致(zhi)通(tong)(tong)信(xin)(xin)中斷或(huo)(huo)通(tong)(tong)信(xin)(xin)設備(bei)損壞事故的(de)(de)(de)原因,往往是由于高(gao)端的(de)(de)(de)網絡(luo)(luo)中存在(zai)低端的(de)(de)(de)交流(liu)電(dian)(dian)(dian)(dian)源(yuan)設備(bei)或(huo)(huo)不科學的(de)(de)(de)供(gong)(gong)(gong)電(dian)(dian)(dian)(dian)方案(an)(an),或(huo)(huo)者電(dian)(dian)(dian)(dian)源(yuan)設備(bei)質(zhi)量低劣,UPS系統(tong)維護(hu)管理不到位等原因。模塊化(hua)真冗余可(ke)并(bing)聯逆(ni)變(bian)電(dian)(dian)(dian)(dian)源(yuan)系統(tong),把交流(liu)供(gong)(gong)(gong)電(dian)(dian)(dian)(dian)方案(an)(an)更(geng)加合理地與通(tong)(tong)信(xin)(xin)網絡(luo)(luo)直流(liu)供(gong)(gong)(gong)電(dian)(dian)(dian)(dian)融為一體(ti),使其(qi)成為更(geng)加標準的(de)(de)(de)通(tong)(tong)信(xin)(xin)供(gong)(gong)(gong)電(dian)(dian)(dian)(dian)方案(an)(an)。采(cai)用模塊化(hua)并(bing)聯逆(ni)變(bian)電(dian)(dian)(dian)(dian)源(yuan)系統(tong)可(ke)以(yi)“在(zai)電(dian)(dian)(dian)(dian)源(yuan)系統(tong)的(de)(de)(de)任何部分出現故障的(de)(de)(de)時候,都(dou)不會造成系統(tong)發生(sheng)停電(dian)(dian)(dian)(dian)事故”,這從其(qi)技術結構(gou)特點(dian)可(ke)以(yi)看(kan)出。

(1)電(dian)(dian)信網絡(luo)整個供(gong)(gong)電(dian)(dian)系統(tong)當中,直(zhi)流(liu)供(gong)(gong)電(dian)(dian)的(de)(de)整流(liu)部分(fen)和交流(liu)供(gong)(gong)電(dian)(dian)的(de)(de)逆變部分(fen)均采用(yong)了各模塊間無主(zhu)從關系的(de)(de)n+1真(zhen)冗(rong)余并(bing)聯系統(tong),在這種真(zhen)冗(rong)余結構當中,當系統(tong)中不論是(shi)整流(liu)部分(fen)還(huan)是(shi)逆變部分(fen)的(de)(de)個別模塊發生(sheng)故障時,故障模塊自動(dong)脫離系統(tong),不影響整個電(dian)(dian)源(yuan)系統(tong)正常供(gong)(gong)電(dian)(dian)。

(2)在電(dian)信機房的(de)(de)直(zhi)流(liu)供(gong)電(dian)系(xi)統中,一(yi)(yi)般都配(pei)置(zhi)了容(rong)量較大的(de)(de)蓄(xu)電(dian)池(chi)(chi)(chi)組(zu),采(cai)用(yong)這(zhe)種方案供(gong)電(dian)時,逆變電(dian)源與直(zhi)流(liu)設備共用(yong)機房的(de)(de)電(dian)池(chi)(chi)(chi)組(zu),機房的(de)(de)直(zhi)流(liu)屏(ping)系(xi)統的(de)(de)可(ke)(ke)(ke)靠性遠(yuan)遠(yuan)超過了UPS的(de)(de)專用(yong)電(dian)池(chi)(chi)(chi),機房專用(yong)電(dian)池(chi)(chi)(chi)的(de)(de)成本也(ye)要低于UPS 用(yong)的(de)(de)12V電(dian)池(chi)(chi)(chi)且(qie)壽命更(geng)高。另一(yi)(yi)方面,機房直(zhi)流(liu)屏(ping)電(dian)池(chi)(chi)(chi)一(yi)(yi)般由(you)用(yong)戶向廠家(jia)直(zhi)接訂購,對其性能要求嚴(yan)格(ge),渠道(dao)比(bi)較正(zheng)規,而UPS的(de)(de)配(pei)套(tao)電(dian)池(chi)(chi)(chi)一(yi)(yi)般由(you)UPS經銷商配(pei)套(tao),用(yong)戶很難把(ba)握其渠道(dao)來(lai)源,難以保證其質量,有長期(qi)維護經驗(yan)和從事UPS技(ji)術(shu)服務(wu)的(de)(de)工程技(ji)術(shu)人員反映,大約有60%的(de)(de)UPS故(gu)障(zhang)是由(you)電(dian)池(chi)(chi)(chi)組(zu)的(de)(de)故(gu)障(zhang)引起。另外,在模(mo)塊化真冗余可(ke)(ke)(ke)并聯逆變電(dian)源系(xi)統中,不同的(de)(de)模(mo)塊可(ke)(ke)(ke)以由(you)不同的(de)(de)直(zhi)流(liu)屏(ping)供(gong)電(dian),這(zhe)樣增加了系(xi)統可(ke)(ke)(ke)靠性。

在(zai)這里需要(yao)指(zhi)出一(yi)點,目前(qian)(qian)國內市場上使(shi)用(yong)的逆(ni)(ni)變(bian)(bian)電(dian)源一(yi)般是采用(yong)了UPS的逆(ni)(ni)變(bian)(bian)部分,這樣的逆(ni)(ni)變(bian)(bian)電(dian)源和電(dian)信(xin)(xin)直流設(she)備共用(yong)直流屏,逆(ni)(ni)變(bian)(bian)器的反灌(guan)衡重(zhong)雜(za)音會對(dui)直流設(she)備造成干擾。陽泉通信(xin)(xin)分公(gong)司(si)使(shi)用(yong)的勁達逆(ni)(ni)變(bian)(bian)電(dian)源模塊,采用(yong)了專為通信(xin)(xin)部門設(she)計的濾(lv)波回路,從技(ji)術角(jiao)度解決了反灌(guan)雜(za)音的干擾,使(shi)直流反灌(guan)雜(za)音遠(yuan)低于前(qian)(qian)端的高頻(pin)開關電(dian)源的影響,該項技(ji)術已(yi)逐步在(zai)國內的逆(ni)(ni)變(bian)(bian)電(dian)源中得到(dao)應用(yong)。

2.系統供電靈活(huo)性

模(mo)塊(kuai)(kuai)化逆變電(dian)源(yuan)系(xi)(xi)(xi)(xi)(xi)統(tong)包含三(san)種功(gong)能單元,即(ji)智能化逆變模(mo)塊(kuai)(kuai)、靜態旁(pang)路開關和(he).。逆變模(mo)塊(kuai)(kuai)是(shi)系(xi)(xi)(xi)(xi)(xi)統(tong)工作的(de)(de)核心(xin)部分,可(ke)以(yi)根(gen)據用戶(hu)負載的(de)(de)容(rong)量來進行配置(zhi)(zhi)。靜態旁(pang)路開關和(he).是(shi)可(ke)選件,用戶(hu)根(gen)據系(xi)(xi)(xi)(xi)(xi)統(tong)的(de)(de)不(bu)同要求(qiu),可(ke)以(yi)方(fang)(fang)便地(di)選擇。由(you)于以(yi)上各單元均(jun)采用了模(mo)塊(kuai)(kuai)化并(bing)(bing)聯(lian)(lian)技術(shu),可(ke)以(yi)使用戶(hu)根(gen)據不(bu)同的(de)(de)技術(shu)要求(qiu)和(he)建設(she)投資進行靈活配置(zhi)(zhi),從而(er)實現不(bu)同的(de)(de)功(gong)能。主要方(fang)(fang)案有(you)以(yi)下(xia)幾種:多模(mo)塊(kuai)(kuai)n+1并(bing)(bing)聯(lian)(lian)系(xi)(xi)(xi)(xi)(xi)統(tong);帶(dai)監控模(mo)塊(kuai)(kuai)的(de)(de)n+1并(bing)(bing)聯(lian)(lian)系(xi)(xi)(xi)(xi)(xi)統(tong);帶(dai)靜態旁(pang)路模(mo)塊(kuai)(kuai)的(de)(de)n+1并(bing)(bing)聯(lian)(lian)系(xi)(xi)(xi)(xi)(xi)統(tong);帶(dai)監控模(mo)塊(kuai)(kuai)及靜態旁(pang)路模(mo)塊(kuai)(kuai)的(de)(de)n+1并(bing)(bing)聯(lian)(lian)系(xi)(xi)(xi)(xi)(xi)統(tong)。

3.易擴展性

逆變(bian)電源可以(yi)熱插拔模塊,可以(yi)在無需(xu)停電情況下增加或減少逆變(bian)模塊的(de)(de)(de)數量來改變(bian)系統的(de)(de)(de)容量,大大方便了用(yong)戶負載容量擴展的(de)(de)(de)需(xu)要。用(yong)戶可以(yi)通(tong)過(guo)改變(bian)逆變(bian)系統的(de)(de)(de)配置來滿足負載變(bian)化的(de)(de)(de)需(xu)要。

4.便于維護性

模塊(kuai)化真冗余(yu)可并聯逆(ni)變(bian)電源系統中如果個別(bie)模塊(kuai)發(fa)生故障,在(zai)不停電的情況下用戶可以自行(xing)熱插拔模塊(kuai),進行(xing)更換。

5.便于電(dian)信機(ji)房內安裝

逆變電源設計(ji)為標準19英(ying)寸(cun)模塊(kuai)或(huo)可內(nei)(nei)嵌到19英(ying)寸(cun)機(ji)(ji)柜內(nei)(nei),功率密度大,體積小,重量(liang)輕,相對其它(ta)電源節(jie)約占地空間。該模塊(kuai)采用(yong)自然降溫方(fang)式(shi),噪音(yin)小,安(an)(an)裝在19英(ying)寸(cun)機(ji)(ji)架(jia)內(nei)(nei),與電信機(ji)(ji)房內(nei)(nei)的其它(ta)設備在物理(li)結構上兼容,便(bian)于設計(ji)和擺放(fang)安(an)(an)裝。

6.經濟性

由于逆變(bian)(bian)模(mo)塊(kuai)(kuai)的(de)電(dian)氣設計技術難度比(bi)(bi)較(jiao)大(da),數字化集成度高(gao),生(sheng)產工藝比(bi)(bi)較(jiao)復雜,導致逆變(bian)(bian)電(dian)源模(mo)塊(kuai)(kuai)的(de)成本相(xiang)對比(bi)(bi)較(jiao)高(gao)。表面(mian)看來,大(da)容量系(xi)統(tong)和UPS價格相(xiang)當,小(xiao)容量系(xi)統(tong)的(de)同容量的(de)逆變(bian)(bian)模(mo)塊(kuai)(kuai)與UPS相(xiang)比(bi)(bi),使(shi)用逆變(bian)(bian)電(dian)源系(xi)統(tong)的(de)投資要略(lve)高(gao),但從(cong)長遠和綜合(he)觀(guan)點來看,這(zhe)種系(xi)統(tong)反而(er)是(shi)一種經濟的(de)方案。

(1)這種逆變電源(yuan)系統為模塊化真冗余(yu)系統,方(fang)便地實(shi)現了n+1冗余(yu)。它與其它并聯或備(bei)份比較(jiao),其冗余(yu)量(liang)(liang)為1/N,投(tou)資(zi)較(jiao)低。一般的(de)(de)UPS或逆變器(qi)需要大量(liang)(liang)的(de)(de)用(yong)于每個環節的(de)(de)備(bei)品(pin)(pin)備(bei)件(jian)(jian)(jian),并且不同容量(liang)(liang)的(de)(de)UPS需要不同規格的(de)(de)備(bei)件(jian)(jian)(jian),用(yong)戶(hu)在采購設(she)備(bei)的(de)(de)同時需要考慮昂貴的(de)(de)備(bei)件(jian)(jian)(jian)投(tou)資(zi)。采用(yong)逆變電源(yuan)系統,無須(xu)為備(bei)品(pin)(pin)備(bei)件(jian)(jian)(jian)進行投(tou)資(zi),只是當個別的(de)(de)模塊出現故障(zhang)時,由廠家為用(yong)戶(hu)提供新的(de)(de)模塊,用(yong)戶(hu)自行更(geng)換即可。

(2)UPS電源一般由(you)廠(chang)家提供服(fu)務,特(te)別是超過保修期后,用戶不得不每年支(zhi)付給(gei)廠(chang)家大(da)量的(de)服(fu)務費用。逆變電源無需廠(chang)家上門服(fu)務,節約了維修服(fu)務投資。

(3)其他電(dian)(dian)(dian)源需要單(dan)獨配置12V電(dian)(dian)(dian)池,電(dian)(dian)(dian)池需要經常更換,累計成本高。采用逆變(bian)電(dian)(dian)(dian)源系統(tong),可以和直流(liu)(liu)(liu)設備共用機房內的大容(rong)量蓄(xu)電(dian)(dian)(dian)池組(zu),交流(liu)(liu)(liu)和直流(liu)(liu)(liu)進行(xing)資源共享,無需重復投資。一(yi)般直流(liu)(liu)(liu)屏的電(dian)(dian)(dian)池使用壽(shou)命(ming)遠遠超過了其它電(dian)(dian)(dian)池,很大程度地節約了電(dian)(dian)(dian)池的成本。

文章編輯:CobiNet(寧波),本公司專注于電訊配件,銅纜綜合布線系列領域產品研發生產七類,六類,超五類屏蔽網線雙絞屏蔽線及相關(guan)模(mo)塊配件,歡(huan)迎來電咨詢0574 88168918;

我們是萬兆網絡模塊萬兆屏蔽模塊10G網絡模塊10G屏蔽模塊keystone jack生產廠家。