解析UPS蓄電池監控技術

發布時間:作(zuo)者(zhe):cobinet 萬兆(zhao)屏蔽模塊(kuai)瀏覽:629次(ci)來源:中國智能機房數據中心
CobiNet(寧波)推薦文章:

人們通常(chang)將蓄電(dian)池(chi)(chi)比(bi)喻為UPS不間斷(duan)供電(dian)系統的(de)心臟,各行(xing)業用戶應從確(que)保運行(xing)質量,生產(chan)安(an)全(quan)和財(cai)產(chan)安(an)全(quan)的(de)角度來重視蓄電(dian)池(chi)(chi)的(de)維護工作,因此(ci)購(gou)置(zhi)蓄電(dian)池(chi)(chi)維護儀表不是消費性的(de)開(kai)支,而是一(yi)種對(dui)安(an)全(quan)的(de)長期投資。

一、UPS蓄電池維護的重要性(xing)

UPS電(dian)(dian)(dian)源是(shi)企(qi)業的(de)動力保證,確(que)保了供(gong)電(dian)(dian)(dian)的(de)連續(xu)性(xing)和(he)安全(quan)性(xing),時刻發(fa)揮著(zhu)重要(yao)的(de)安全(quan)保障作用。蓄(xu)電(dian)(dian)(dian)池是(shi)UPS重要(yao)組成部分,作為動力提供(gong)的(de)最后保障,無疑是(shi)UPS電(dian)(dian)(dian)源的(de)最后一(yi)道保險。據調查,由UPS電(dian)(dian)(dian)源無法正(zheng)常供(gong)電(dian)(dian)(dian)而引發(fa)的(de)數(shu)據中(zhong)心事故(gu)中(zhong)有50%以上是(shi)由蓄(xu)電(dian)(dian)(dian)池故(gu)障引發(fa)的(de),蓄(xu)電(dian)(dian)(dian)池是(shi)UPS電(dian)(dian)(dian)源事故(gu)發(fa)生率居高(gao)不下(xia)的(de)一(yi)個環節,由此(ci)可(ke)(ke)見提高(gao)蓄(xu)電(dian)(dian)(dian)池運行安全(quan)可(ke)(ke)靠的(de)必要(yao)性(xing)和(he)迫切性(xing)。

UPS蓄(xu)電(dian)池(chi)普遍缺乏正確(que)的日常維(wei)護和(he)準確(que)的檢測手段(duan),這(zhe)為以后UPS正常供電(dian)埋(mai)下了重大安全隱患,有部分(fen)用(yong)(yong)戶(hu)通常是(shi)等(deng)到事(shi)故(gu)發(fa)(fa)生,才知道(dao)是(shi)UPS電(dian)池(chi)出現故(gu)障無法正常供電(dian)了。如何提高(gao)(gao)UPS電(dian)源(yuan)中蓄(xu)電(dian)池(chi)監測管理手段(duan)和(he)水平(ping),降低或杜絕蓄(xu)電(dian)池(chi)事(shi)故(gu)發(fa)(fa)生率,無疑對于用(yong)(yong)戶(hu)具(ju)有很高(gao)(gao)的經濟價值。提高(gao)(gao)UPS蓄(xu)電(dian)池(chi)運行的安全可靠性,是(shi)目(mu)前(qian)困(kun)擾用(yong)(yong)戶(hu)普遍存在(zai)的難題(ti)。

二、UPS蓄電池維護現狀(zhuang)及安全隱患

1、蓄(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)壽(shou)命無法(fa)達到設計要(yao)求,在(zai)實際應(ying)用(yong)(yong)中(zhong),蓄(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)往(wang)往(wang)在(zai)使(shi)用(yong)(yong)1年(nian)后(hou)就(jiu)開始出現劣(lie)化(hua),使(shi)用(yong)(yong)超(chao)過3年(nian)的(de)(de)(de)蓄(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)劣(lie)化(hua)程(cheng)度非常嚴重(zhong),幾(ji)乎很少能夠達到標稱容量。這(zhe)其中(zhong)存(cun)在(zai)兩個方面的(de)(de)(de)問(wen)題,其一,蓄(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)廠家對于(yu)(yu)蓄(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)的(de)(de)(de)使(shi)用(yong)(yong)壽(shou)命年(nian)限是(shi)在(zai)較為理想(xiang)的(de)(de)(de)狀態(tai)下預(yu)測的(de)(de)(de);其二(er),在(zai)使(shi)用(yong)(yong)中(zhong)對于(yu)(yu)蓄(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)的(de)(de)(de)管理以(yi)及維護(hu),沒(mei)有(you)有(you)效(xiao)的(de)(de)(de)進(jin)行,造成蓄(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)在(zai)劣(lie)化(hua)早期,沒(mei)有(you)及時(shi)發(fa)現落后(hou)電(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi),致使(shi)劣(lie)化(hua)積累、加劇,容量累積虧損導致蓄(xu)電(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)過早報(bao)廢。

2、對于蓄(xu)電(dian)(dian)池的充放電(dian)(dian)缺乏記錄(lu)及監控,蓄(xu)電(dian)(dian)池運行情況不明(ming)。

3、由于(yu)沒有良好的(de)手段以及(ji)管理(li),蓄電(dian)池(chi)的(de)使用者對于(yu)蓄電(dian)池(chi)運行情況缺乏足夠(gou)的(de)了解,特別(bie)是對于(yu)蓄電(dian)池(chi)歷(li)史數據(ju)的(de)整(zheng)(zheng)理(li)以及(ji)分(fen)析。而(er)這些數據(ju)的(de)整(zheng)(zheng)理(li)與分(fen)析需要(yao)較強的(de)專業知識。

4、對于蓄(xu)電池性能狀況不明(ming),特別是(shi)UPS蓄(xu)電池是(shi)否(fou)具備瞬間大電流供電能力(li)不了解?

5、對于蓄(xu)(xu)電(dian)池(chi)性能狀況,如蓄(xu)(xu)電(dian)池(chi)的電(dian)壓均(jun)衡(heng)性、當(dang)前容量,無(wu)法(fa)清楚實時了解。

6、缺(que)乏溫度補償及環境溫度的(de)監測(ce)。

7、UPS蓄電池(chi)缺乏檢(jian)測(ce)手段和維(wei)護儀表,重視程度不(bu)足。

8、目前有(you)相當多蓄電池的(de)維護人(ren)員,受到(dao)誤導(dao),認(ren)為(wei) 免維護 就是不(bu)需維護。認(ren)為(wei)采用三(san)年到(dao)期(qi)就更換電池的(de)措施能一(yi)勞永(yong)逸解(jie)決并(bing)代(dai)替維護檢(jian)測。

三、UPS蓄電池的日常檢測

防范(fan)勝于(yu)(yu)救災,盡早發存蓄(xu)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)存在隱患,將斷電(dian)(dian)(dian)(dian)(dian)災害消除在未發生時(shi),要比制(zhi)定應急方案更為有效(xiao)。INNET BCSU-240C系列(lie)是一款功(gong)(gong)能(neng)(neng)全(quan)面、操(cao)作簡(jian)易的(de)蓄(xu)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)監(jian)測(ce)管理系統。其主要功(gong)(gong)能(neng)(neng)有:實時(shi)顯(xian)示(shi)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)的(de)總電(dian)(dian)(dian)(dian)(dian)壓、總電(dian)(dian)(dian)(dian)(dian)流(liu)、每(mei)節(jie)(jie)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)的(de)電(dian)(dian)(dian)(dian)(dian)壓、溫度、最(zui)高(gao)4節(jie)(jie)單體電(dian)(dian)(dian)(dian)(dian)壓、最(zui)低4節(jie)(jie)單體電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)、電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)的(de)工作狀(zhuang)態等信息(xi);多種異(yi)(yi)常(chang)(chang)(chang)報(bao)警(jing)(jing)功(gong)(gong)能(neng)(neng):總電(dian)(dian)(dian)(dian)(dian)壓異(yi)(yi)常(chang)(chang)(chang)、電(dian)(dian)(dian)(dian)(dian)流(liu)異(yi)(yi)常(chang)(chang)(chang)、溫度異(yi)(yi)常(chang)(chang)(chang)、單體電(dian)(dian)(dian)(dian)(dian)壓異(yi)(yi)常(chang)(chang)(chang)、內(nei)阻(zu)異(yi)(yi)常(chang)(chang)(chang)、模(mo)塊通(tong)訊異(yi)(yi)常(chang)(chang)(chang)、浮充(chong)電(dian)(dian)(dian)(dian)(dian)壓異(yi)(yi)常(chang)(chang)(chang)等報(bao)警(jing)(jing);自(zi)動識別電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)組的(de)工作狀(zhuang)態,顯(xian)示(shi)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)處于(yu)(yu):浮充(chong)、放(fang)電(dian)(dian)(dian)(dian)(dian)、均充(chong)等狀(zhuang)態;充(chong)放(fang)電(dian)(dian)(dian)(dian)(dian)過(guo)程(cheng)數(shu)據(ju)(ju)存儲(chu)記(ji)(ji)錄功(gong)(gong)能(neng)(neng):能(neng)(neng)自(zi)動記(ji)(ji)錄8次10小(xiao)時(shi)以(yi)上的(de)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)充(chong)放(fang)電(dian)(dian)(dian)(dian)(dian)數(shu)據(ju)(ju);內(nei)阻(zu)測(ce)試及數(shu)據(ju)(ju)記(ji)(ji)錄:只要電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)處于(yu)(yu)放(fang)電(dian)(dian)(dian)(dian)(dian)狀(zhuang)態,立即(ji)測(ce)試每(mei)節(jie)(jie)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)的(de)內(nei)阻(zu)數(shu)據(ju)(ju);記(ji)(ji)錄并存儲(chu)蓄(xu)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)在運行過(guo)程(cheng)中發生的(de)異(yi)(yi)常(chang)(chang)(chang)事件上,能(neng)(neng)查詢30次歷(li)史報(bao)警(jing)(jing)和實時(shi)報(bao)警(jing)(jing)功(gong)(gong)能(neng)(neng);實時(shi)監(jian)測(ce),發現落后(hou)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi),提(ti)前預報(bao)蓄(xu)電(dian)(dian)(dian)(dian)(dian)池(chi)(chi)(chi)(chi)(chi)失效(xiao)趨勢(shi)等。

四、系統安全特性

INNET BCSU-240C系(xi)列蓄(xu)電池在線監測管理系(xi)統(tong)(tong)(tong)在設計上充(chong)分考慮(lv)了各類使(shi)用(yong)場合(he)及各類意外事故對系(xi)統(tong)(tong)(tong)本身及同系(xi)統(tong)(tong)(tong)配套使(shi)用(yong)的(de)(de)(de)各類設備沖(chong)擊(ji),采用(yong)了多種抗沖(chong)擊(ji)、高容錯的(de)(de)(de)手段(duan),完全采用(yong)高性能(neng)的(de)(de)(de)元器(qi)件,使(shi)得系(xi)統(tong)(tong)(tong)具(ju)有很(hen)高的(de)(de)(de)安全特性。具(ju)有很(hen)好的(de)(de)(de)獨立運行能(neng)力,不受用(yong)戶系(xi)統(tong)(tong)(tong)的(de)(de)(de)工作狀況影(ying)響(xiang),也不影(ying)響(xiang)用(yong)戶系(xi)統(tong)(tong)(tong)的(de)(de)(de)工作狀態。

1、系統容錯性

儀表對(dui)充電(dian)(dian)系統和工作(zuo)回(hui)路(lu)(lu)也無(wu)任(ren)何干擾,模(mo)塊(kuai)同(tong)蓄(xu)電(dian)(dian)池的(de)(de)連接部分(fen)均(jun)有防過(guo)流保(bao)險(1A),避(bi)免連接導(dao)線自(zi)身短(duan)路(lu)(lu)或模(mo)塊(kuai)的(de)(de)故障對(dui)蓄(xu)電(dian)(dian)池的(de)(de)造成(cheng)傷害。各檢(jian)(jian)測通道(dao)均(jun)采(cai)用(yong)(yong)(yong)高阻抗輸入方(fang)式,檢(jian)(jian)測回(hui)路(lu)(lu)的(de)(de)電(dian)(dian)流小(xiao)(xiao)于微安級,對(dui)蓄(xu)電(dian)(dian)池無(wu)任(ren)何不(bu)良影響。模(mo)塊(kuai)同(tong)蓄(xu)電(dian)(dian)池的(de)(de)連接采(cai)用(yong)(yong)(yong)單線連接方(fang)式,連接端(duan)都安裝(zhuang)過(guo)電(dian)(dian)流保(bao)險(0.5A),避(bi)免連接導(dao)線自(zi)身短(duan)路(lu)(lu)或模(mo)塊(kuai)的(de)(de)故障對(dui)蓄(xu)電(dian)(dian)池的(de)(de)造成(cheng)傷害。采(cai)用(yong)(yong)(yong)小(xiao)(xiao)功(gong)率(lv)元(yuan)器(qi)件設(she)計,系統工作(zuo)功(gong)耗低,對(dui)用(yong)(yong)(yong)戶(hu)(hu)供電(dian)(dian)系統要求不(bu)高,不(bu)影響用(yong)(yong)(yong)戶(hu)(hu)供電(dian)(dian)線路(lu)(lu)。完(wan)全獨立于用(yong)(yong)(yong)戶(hu)(hu)設(she)備工作(zuo)。

2、具有防過壓(ya)過流高頻(pin)磁場(chang)干擾特性

BCSU-240C系(xi)列蓄電池在線監測管理系(xi)統采用(yong)先進的電源變換(huan)技術,工作電壓(ya)范圍寬,防(fang)(fang)過(guo)流過(guo)壓(ya)能力(li)強,系(xi)統設(she)計有防(fang)(fang)浪(lang)涌電路,可在高頻強磁場(chang)工作環境下(xia)正(zheng)常(chang)運行。

3、電磁兼容性

BCSU-240C系(xi)(xi)(xi)列蓄(xu)電池在線監測管理(li)系(xi)(xi)(xi)統(tong)在電路(lu)設計及結構設計上充分考慮電磁兼(jian)容的(de)特(te)性,電磁輻(fu)射(she)量小于國家標準。采用金屬(shu)外殼,具有很(hen)好(hao)的(de)屏蔽效果。系(xi)(xi)(xi)統(tong)本身(shen)對外界無任(ren)何電磁干擾(rao)。

4、在線可維護特性

BCSU-240C系(xi)列蓄電池(chi)在線(xian)監測管(guan)理系(xi)統采用模塊化設計,模塊獨立性良好(hao),在線(xian)維(wei)護(hu)性強,在線(xian)維(wei)護(hu)不影響用戶系(xi)統的正常工作。

5、阻燃性

BCSU-240C系列蓄電池在線監測管理系統采用(yong)阻燃(ran)(ran)特(te)性良好的(de)(de)元器件,系統本(ben)身的(de)(de)短路過流等原因造成(cheng)的(de)(de)故障不會引起明火燃(ran)(ran)燒。

6、防爆性

BCSU-240C系列蓄電池在線監(jian)測(ce)管理系統采(cai)用(yong)電子式(shi)繼(ji)電器(qi)(qi),無通道切換火花,無產生明火接觸連接器(qi)(qi)件,可用(yong)于高防(fang)爆(bao)要(yao)求的石(shi)油化工等行業。

INNET BCSU蓄電(dian)(dian)池在(zai)線監控系統(tong)已陸續在(zai)福(fu)建省電(dian)(dian)力公司(si)新大樓(lou)、廈(sha)門電(dian)(dian)信公司(si)IDC數據機房、燕山石化集(ji)團(tuan)(tuan)聚丙烯分廠(chang)(chang)、燕山石化集(ji)團(tuan)(tuan)煉(lian)油(you)廠(chang)(chang)、中國民(min)航空中交通管理局(ju)、蘭(lan)州(zhou)中川機場、華能電(dian)(dian)廠(chang)(chang)山東(dong)德州(zhou)分公司(si)等企業的數據中心投(tou)入使用。



文章編輯:CobiNet(寧波),本(ben)公司專注(zhu)于(yu)電(dian)訊(xun)配件(jian),銅纜(lan)綜合布線系列領域(yu)產品研發(fa)生(sheng)產超五類,六(liu)類,七(qi)類屏蔽網線/屏蔽模塊及(ji)相(xiang)關模塊配件(jian),歡迎來電(dian)咨(zi)詢0574 88168918,網址aliance.cn

我們是萬兆屏蔽模塊10G屏蔽模塊屏蔽線生產廠家。